ALL Products

ERW Motor Gearboxes: Electric motors for greenhouse

 ERW Motor Gearboxes: Electric motors for greenhouse

Electric motors, 3-phase Euro voltage (type A) for greenhouse

Electric motors for RW motor gearboxes, 3-phase eurovoltage version.

  • Suitable for use on 400 V and 50 Hz in star circuit;
  • Suitable for use on 230 V and 50 Hz in delta circuit;
  • Electric motors are standard tropic-proof and conform to protection class IP55;
  • Electric motors are insulation class F (40ºC);
  • Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes;
  • Manual drive enabled by means of a hexagon socket in the electric motor shaft.
Art. no. CSA/UL (C/U) m (kg) Hexagon (mm) Cable gland P (kW) - 50Hz I (A) - 400V\50Hz I (A) - 230V\50Hz cos ϕ - 50Hz PTC Thermistor 150ºC
763010 3,0 6 M20 0,09 0,41 0,71 0,60
763097 11,3 8 M20 2,00 4,5 7,8 0,75
763397 11,3 8 M20 2,00 4,5 7,8 0.86 PTC Thermistor150ºC
763020 3,5 6 M20 0,12 0,46 0,80 0,60
763030 5,2 6 M20 0,25 0,70 1,21 0,77
763035 3,7 6 M20 0,30 1,08 1,86 0,73
763040 5,2 6 M20 0,37 1,1 1,9 0,75
763060 8,0 8 M20 0,55 1,4 2,4 0,77
763070 8,1 8 M20 0,75 2,0 4,8 0,80
763080 9,6 8 M20 1,10 2,8 4,8 0,83
763085 9,9 8 M20 1,10 2,8 4,8 0,83
763090 11,0 8 M20 1,50 4,5 7,8 0,75
763095 11,3 8 M20 1,50 4,5 7,8 0,75
753020 6 M20 0,18 0,65 1,06 0,96
Hongtai Liu Road, Xiaoshan District

Hangzhou City

+86-13205713851

Mon to Fri 9am to 6 pm

sales@greenhousegearbox.com

Send us your query anytime!

Electric motors, 3-phase wide voltage CSA/UL or CSA (type B) for greenhouse

Electric motors for RW motor gearboxes, 3-phase wide voltage version.

  • Suitable for use on 400-415 V and 50 Hz in star circuit;
  • Suitable for use on 400-480 V and 60 Hz in star circuit;
  • Suitable for use on 208 V and 50/60 Hz in delta circuit;
  • Electric motors have CSA approval mark standard;
  • Electric motors are standard tropic-proof and conform to protection class IP55;
  • Electric motors are insulation class F (40ºC);
  • Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes;
  • Manual drive enabled by means of a hexagon socket in the electric motor shaft.
Art. no. CSA/UL (C/U) m (kg) Hexagon (mm) Cable gland P (kW) - 50Hz P (kW) - 60Hz I (A) - 200-208V\50Hz I (A) - 380-415V\50Hz I (A) - 200-277V\60Hz I (A) - 380-480V\60Hz cos ϕ - 200-208V/50Hz cos ϕ - 380-415V/50Hz cos ϕ - 200-277V/60Hz cos ϕ - 380-480V/60Hz PTC Thermistor 150ºC
764002 CU 2,9 6 M20 0,09 0,11 0,75 0,45 0,85 0,50 0,75 0,45 0,85 0,50
704124 C (-) 8 M20 3,00 3,0 11,5 8,5 11,5 8,5 0,90 0,67 0,67 0,67
704297 CSA 23,725 8 M20 2,0 2,4 9,5 6,0 10,0 6,0 0,75 0,6 0,65 0,65
704297P CSA 23,725 8 M20 2,0 2,4 9,5 6,0 10,0 6,0 0,75 0,6 0,65 0,65 PTC Thermistor 150ºC
704272P C 15,3 8 M20 1,10 1,32 5,5 3,6 6,5 3,6 0,75 0,55 0,60 0,60
704292P C 18,1 8 M20 1,50 1,80 7,0 4,6 8,0 4,4 0,75 0,60 0,65 0,65
764012 CU 2,9 6 M20 0,12 0,14 1,05 0,60 1,05 0,60 0,62 0,62 0,70 0,70
764022 CU 5,0 6 M20 0,25 0,30 1,90 1,40 1,90 1,30 0,60 0,50 0,60 0,50
704092 C 17,1 8 M20 1,50 1,80 7,0 4,6 8,0 4,4 0,75 0,60 0,65 0,65
704032 C 6,5 6 M20 0,37 0,44 2,20 1,45 2,4 1,4 0,65 0,55 0,55 0,55
704042P C 8,7 8 M20 0,55 0,66 3,2 2,0 3,6 1,9 0,70 0,55 0,60 0,60
704052P C 10,2 8 M20 0,75 0,90 4,6 3,0 5,0 2,8 0,70 0,55 0,70 0,55
704072P 14,5 8 M20 1,10 1,32 5,5 3,6 6,5 3,6 0,75 0,55 0,60 0,60
763832 6 M20 0,25 0,8 0,76 PTC Thermistor 150°C
763842 6 M20 0,4 1,3 0,77 PTC Thermistor 150°C
764032 UL(C-US) 6,9 5 M20 0,37 0,44 2,3 1,3 2,6 1,5 0,86 0,61 0,83 0,65
Hongtai Liu Road, Xiaoshan District

Hangzhou City

+86-13205713851

Mon to Fri 9am to 6 pm

sales@greenhousegearbox.com

Send us your query anytime!

Electric motors, 24 V DC (type H) for greenhouse

Electric motors for RW motor gearboxes, 3-phase 600V version.

  • Suitable for use on 600V and 60 Hz in star circuit;
  • Suitable for use on 346V and 60 Hz in delta circuit;
  • Electric motors have CSA approval mark standard;
  • Electric motors are standard tropic-proof and conform to protection class IP55;
  • Electric motors are insulation class F (40ºC);
  • Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes;
  • Manual drive enabled by means of a hexagon socket in the electric motor shaft.
Art. no. CSA/UL (C/U) m (kg) Jaw opening (mm) Cable gland P (kW) - 60Hz I (A) - 346V\60Hz I (A) - 600V\60Hz cos ϕ - 346V/60Hz cos ϕ - 600V/60Hz
703632 C 6,5 6 M20 0,44 1,50 0,86 0,70 0,70
703642 C 8,8 8 M20 0,66 2,70 1,55 0,60 0,60
703662 C 9,8 8 M20 1,10 3,60 2,10 0,70 0,70
703692 C 17,4 8 M20 1,80 5,8 3,4 0,65 0,65
763795 11,3 8 M20 2,16
703792 C 18,2 8 M20 1,80 5,8 3,4 0,65 0,65
703724 C 15,3 8 M20 3,60 11,0 6,50 0,65 0,65
Hongtai Liu Road, Xiaoshan District

Hangzhou City

+86-13205713851

Mon to Fri 9am to 6 pm

sales@greenhousegearbox.com

Send us your query anytime!

Frequency controlled electric motors (type I) for greenhouse

Electric motors for RW motor gearboxes. 1-phase 230 V version.

  • Suitable for use on 230 V and 50/60 Hz circuit;
  • Electric motors up to 0.18 kW with 3-wire connection (duty capacitor);
  • Electric motors from 0.25 kW have CSA approval mark standard;
  • Electric motors are standard tropic-proof and conform to protection class IP55;
  • Electric motors are insulation class F (40ºC);
  • Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes;
  • Manual drive enabled by means of a hexagon socket in the electric motor shaft.
Art. no. CSA/UL (C/U) m (kg) Hexagon (mm) Cable gland P (kW) - 50Hz P (kW) - 60Hz I (A) - 220V\50Hz I (A) - 240V\50Hz I (A) - 220V\60Hz I (A) - 240V\60Hz cos ϕ - 220V/50Hz cos ϕ - 240V/50Hz cos ϕ - 220V/60Hz cos ϕ - 240V/60Hz PTC Thermistor 150ºC
761001 3,5 6 M20 0,09 0,11 0,9 1,0 1,1 1,1 0,99 0,99 0,96 0,96
761016 7,3 6 M20 0,18 0,22 1,83 2,0 2,24 2,25 0,84 0,84 0,96 0,96
Hongtai Liu Road, Xiaoshan District

Hangzhou City

+86-13205713851

Mon to Fri 9am to 6 pm

sales@greenhousegearbox.com

Send us your query anytime!

Electric motors, 3-phase 600V\60Hz (type C) for greenhouse

Electric motors for RW motor gearboxes, 3-phase 600V version.

  • Suitable for use on 600V and 60 Hz in star circuit;
  • Suitable for use on 346V and 60 Hz in delta circuit;
  • Electric motors have CSA approval mark standard;
  • Electric motors are standard tropic-proof and conform to protection class IP55;
  • Electric motors are insulation class F (40ºC);
  • Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes;
  • Manual drive enabled by means of a hexagon socket in the electric motor shaft.
Art. no. CSA/UL (C/U) m (kg) Jaw opening (mm) Cable gland P (kW) - 60Hz I (A) - 346V\60Hz I (A) - 600V\60Hz cos ϕ - 346V/60Hz cos ϕ - 600V/60Hz
703632 C 6,5 6 M20 0,44 1,50 0,86 0,70 0,70
703642 C 8,8 8 M20 0,66 2,70 1,55 0,60 0,60
703662 C 9,8 8 M20 1,10 3,60 2,10 0,70 0,70
703692 C 17,4 8 M20 1,80 5,8 3,4 0,65 0,65
763795 11,3 8 M20 2,16
703792 C 18,2 8 M20 1,80 5,8 3,4 0,65 0,65
703724 C 15,3 8 M20 3,60 11,0 6,50 0,65 0,65
Hongtai Liu Road, Xiaoshan District

Hangzhou City

+86-13205713851

Mon to Fri 9am to 6 pm

sales@greenhousegearbox.com

Send us your query anytime!

Electric motors, 1-phase 230 V (3-wire, type D) for greenhouse

Electric motors for RW motor gearboxes. 1-phase 230 V version.

  • Suitable for use on 230 V and 50/60 Hz circuit;
  • Electric motors up to 0.18 kW with 3-wire connection (duty capacitor);
  • Electric motors from 0.25 kW have CSA approval mark standard;
  • Electric motors are standard tropic-proof and conform to protection class IP55;
  • Electric motors are insulation class F (40ºC);
  • Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes;
  • Manual drive enabled by means of a hexagon socket in the electric motor shaft.
Art. no. CSA/UL (C/U) m (kg) Hexagon (mm) Cable gland P (kW) - 50Hz P (kW) - 60Hz I (A) - 220V\50Hz I (A) - 240V\50Hz I (A) - 220V\60Hz I (A) - 240V\60Hz cos ϕ - 220V/50Hz cos ϕ - 240V/50Hz cos ϕ - 220V/60Hz cos ϕ - 240V/60Hz PTC Thermistor 150ºC
761001 3,5 6 M20 0,09 0,11 0,9 1,0 1,1 1,1 0,99 0,99 0,96 0,96
761016 7,3 6 M20 0,18 0,22 1,83 2,0 2,24 2,25 0,84 0,84 0,96 0,96
Hongtai Liu Road, Xiaoshan District

Hangzhou City

+86-13205713851

Mon to Fri 9am to 6 pm

sales@greenhousegearbox.com

Send us your query anytime!

Electric motors, 1-phase 230 V (5-wire, type E) for greenhouse

Electric motors for RW motor gearboxes. 1-phase 230 V version.

  • Suitable for use on 230 V and 50/60 Hz circuit;
  • Electric motors from 0.25 kW with 5-wire connection (duty and start capacitor);
  • Electric motors from 0.25 kW have CSA approval mark standard;
  • Electric motors are standard tropic-proof and conform to protection class IP55;
  • Electric motors are insulation class F (40ºC);
  • Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes;
  • Manual drive enabled by means of a hexagon socket in the electric motor shaft.
Art. no. CSA/UL (C/U) m (kg) Hexagon (mm) Cable gland P (kW) - 50Hz P (kW) - 60Hz I (A) - 220V\50Hz I (A) - 240V\50Hz I (A) - 220V\60Hz I (A) - 240V\60Hz cos ϕ - 220V/50Hz cos ϕ - 240V/50Hz cos ϕ - 220V/60Hz cos ϕ - 240V/60Hz PTC Thermistor 150ºC
701021P C 7,2 6 M20 0,25 0,30 2,1 2,35 2,0 2,0 0,80 0,72 0,90 0,90
761032 C 9,4 6 M20 0,37 0,44 2,9 2,9 2,7 2,7 0,87 0,87 0,98 0,98
761042 C 11,8 6 M20 0,55 0,66 4,5 4,5 4,5 4,5 0,85 0,85 0,90 0,90
701062 C 14,9 6 M20 1,10 1,30 7,0 6,5 8,0 7,0 0,95 0,90 0,98 0,98
Hongtai Liu Road, Xiaoshan District

Hangzhou City

+86-13205713851

Mon to Fri 9am to 6 pm

sales@greenhousegearbox.com

Send us your query anytime!

Electric motors, 1-phase 115 V\60 Hz (3-wire, type F) for greenhouse

Electric motors for RW motor gearboxes. 1-phase 115 V\60 Hz version.

  • Suitable for use on 115 V and 60 Hz circuit;
  • Up to 0.18 kW with 3-wire connection (duty capacitor);
  • Electric motors have CSA approval mark standard;
  • Electric motors are standard tropic-proof and conform to protection class IP55;
  • Electric motors are insulation class F (40ºC);
  • Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes;
  • Manual drive enabled by means of a hexagon socket in the electric motor shaft.
Art. no. CSA/UL (C/U) m (kg) Hexagon (mm) Cable gland P (kW) - 60Hz I (A) - 110V\60Hz I (A) - 115V\60Hz cos ϕ - 110V\60Hz cos ϕ - 115V\60Hz PTC Thermistor 150ºC
761202 CU 3,5 6 M20 0,09 2,5 2,5 0,95 0,95
701217 C 6,2 6 M20 0,18 3,6 4,0 0,90 0,85
761218 UL (C-US) 7,3 5 M20 0,18 4,0 4,0 0,9 0,9 PTC Thermistor 150°C 0,96
Hongtai Liu Road, Xiaoshan District

Hangzhou City

+86-13205713851

Mon to Fri 9am to 6 pm

sales@greenhousegearbox.com

Send us your query anytime!

Electric motors, 1-phase 115 V\60 Hz (5-wire, type G) for greenhouse

Electric motors for RW motor gearboxes. 1-phase 115 V\60 Hz version.

  • Suitable for use on 115 V and 60 Hz circuit;
  • Electric motors from 0.25 kW with 5-wire connection (duty and start capacitor);
  • Electric motors have CSA approval mark standard;
  • Electric motors are standard tropic-proof and conform to protection class IP55;
  • Electric motors are insulation class F (40ºC);
  • Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes;
  • Manual drive enabled by means of a hexagon socket in the electric motor shaft.
Art. no. CSA/UL (C/U) m (kg) Hexagon (mm) Cable gland P (kW) - 60Hz I (A) - 110V\60Hz I (A) - 115V\60Hz cos ϕ - 110V\60Hz cos ϕ - 115V\60Hz PTC Thermistor 150ºC
701232P C 8,1 8 M20 0,37 5,5 6,0 0,85 0,8
Hongtai Liu Road, Xiaoshan District

Hangzhou City

+86-13205713851

Mon to Fri 9am to 6 pm

sales@greenhousegearbox.com

Send us your query anytime!